In normal
operation the Westfalia bilge water separator feedpump suction is on the oily
bilge tank(15C). There is the possibility to get suction from the 1st,
2nd and 3rd stage of 15C. The Westfalia can be used in
tank cleaning mode(recirculation over 15C) and the so called overboard
mode(from 15C to 15PS). The recirculation water always goes back to the 1st
stage.
STARTING the
Westfalia bilge water separator
·
Check
if correct suction valve of 15C is open(1st, 2nd or 3rd
stage)
·
Check
if the suction valve from 15C to the bilge water separators is open
·
Check
if the suction valve in front of the suction filter is open
·
Check
if the main suction valve in front of the Westfalia feedpump is open
·
Check
if the technical water supply valve to the Westfalia is open
·
Check
if the technical water supply to the OCM is open
·
Check
if the air supply valve is open
·
Check
if the sample water cooler cooling water valves are open
·
Check
if the return valve to 15C is open
·
Check
if the inlet valve of 15PS is open
·
Start
the feed pump by pressing: FEED PUMP START
·
When
the feedpump is running SLOWLY open up the main steam valve.
·
Start
the Westfalia separator by pressing: SEPARATOR START
Now wait until the feed water temperature is > 75°C and the Westfalia separator has reached the correct RPM’s.
If this is the case the display will indicate READY.
·
Press
PROGRAM 1.
·
Press
the TANK CLEANING YES/NO button if you want to recirculate over 15C or;
·
Press
the OVERBOARD YES/NO button if you want to process 15C to 15PS via the OCM.
In order to
recirculate over intermediate bilge water tank 15PS(tank cleaning) manifold
valves ① and ⑨ have to be changed over and
the purifier has to be in tank cleaning mode.
When you want to recirculate over 15PS
check if the correct inlet valve of 15PS is open.
NOTE: In tank cleaning mode the Westfalia OCM
is not in operation. There is no sample water going trough the OCM. The OCM is
only in operation in the so called overboard mode.
NOTE: The feed pump can be selected manual
or automatic. The automatic mode can only be used in the so called overboard
mode. In tank cleaning mode the automatic function is not operational(Selector
switch: FC FEED PUMP - options: A or M)
STOPPING the
Westfalia bilge water separator
·
Press
the OVERBOARD YES/NO button to select NO.
·
Press
PROGRAM 0, the Westfalia will discharge.
·
After
the discharge stop the Westfalia separator by pressing: SEPARATOR STOP
·
Close
the manual steam valve
·
Wait
until the temperature has dropped below 45°C
·
Stop
the feed pump by pressing: FEED PUMP STOP
·
Close
the main suction valve before the feedpump
·
Close
the technical water supply valve to the Westfalia
·
Close
the air supply valve
·
Close
the sample water cooler cooling water valves
·
Flush
the OCM with technical water for at least 30 seconds.
Tidak ada komentar: