Step 1:- isolate the diesel engine you want to
drain the EGB.
1. Set
engine to manual control on engine control room local panel.
2. Put the
engine last in sequence on VDU
3. Start the
PRE-LUB and JACKING pumps on MANUAL
3. On the
engine, pull the emergency stop handle beside the local control stand down.
Lock out tag out the handle in the down position.
4. CLOSE the
starting air valve and lock out in the closed position.
5. OPEN the
starting air drain and lock with provided key lock.
Step 2:- Stop and isolate the EGB Circulation
pump
In the
relevant 11kv switch board room. Stop the EGB pumps by the emergency stop, Open
the breaker and switch the control to local. Lock out the breaker with scissors
clamp.
Step 3:- Throttle the inlet valve to the EGB circ
pump until almost closed
This valve
is left open to keep the pump warm. To prevent the seals from leaking
Step 4:- SHUT the outlet valve of the EGB circ
pump, and then lock out tag out with cable and locking clamp.
Step 5:- SHUT both inlet valves to the EGB in
the engine casing. Lock out both valves with one long cable and locking clamp.
Step 6:- SHUT both outlet valves to the EGB,
lock both valves together with one long cable and locking clamp.
Step 7:- CRACK OPEN the drain and the vent on
the EGB
OVERBOARD
VALVES MUST BE OPEN to drain the EGB
Warning do
not open to much this will cause steaming on A deck form the drains.
Step 8:- OPEN the drain line after the outlet
of the circ pump. This will prevent banging when filling up