The clean
bilge overboard pump is used to pump water directly from Clean bilge water tank
18C overboard via the Whitebox.
Before the
clean bilge overboard pump can be started to process bilge water overboard we
have to ask permission from the on duty officer on the bridge. If we have
permission from the on duty officer on the bridge we need a starting time and a
starting position to enter in the appropriate log books.
Starting the clean
bilge overboard pump
·
Open
the main overboard valve. (This valve is normally locked. The key is in the
ECR).
·
Open
the suction valve of Clean bilge water tank 18C
·
Open
the suction valve from Clean bilge water tank 18C to the clean bilge overboard
pump
·
Open
the suction and discharge valve of the clean bilge overboard pump
·
Open
the technical water supply of the OCM
·
Check
if the correct inlet valve of 15PS is open(in case of high ppm
alarm/recirculation)
·
Check
if the Whitebox outlet valve is open
·
Start
the Clean bilge overboard pump
·
Check
the suction and discharge pressures of the pump
Check
if the Whitebox is operating properly
Stopping the clean bilge overboard pump
·
Stop
the Clean bilge overboard pump by pressing the emergency stop
·
Close
the inlet and outlet valve of the clean bilge overboard pump
·
Close
the suction valve from the clean bilge water tank 18C to the clean bilge
overboard pump
·
Close
the suction valve of Clean bilge water tank 18C
·
Flush
the OCM for at least 30 seconds
·
Close
the technical water supply to the OCM
·
Close
the return valve to 15PS
·
Close
and lock the overboard valve.
When the overboard
valve is closed the bridge needs to be called for a stop time and a stop
position.