GENERAL
·
Ask
the chief engineer for permission and inform the bridge that maintenance will
be carried out ( if applicable, i.e. maintenance on propulsion equipment /
stabilizers / safety and lifesaving equipment etc ).
·
Inform
senior watch engineer (SWE) about all maintenance that will be performed in the
engine room.
·
Follow
the log/tag-out procedure as per MR600 section 5.
·
Use
necessary personal protection equipment (PPE).
JOB INSTRUCTION
·
Switch the engine to 1 – local
·
isolate the starting air on the engine, see “engine starting air isolation procedure”.
·
At the control stand place the emergency – off lever in the stop position ( see picture)
·
Refer to drawing “ main engine LT cooling water isolation V/V”s and :
Ø
Close valve ½ and attach the related tag.
Ø
Close the valve 2/2 and attach the related tag.
Ø
Relief the engine LT system pressure by opening
the drain valve and attach the related tag.
·
On the ECR mimic panel display “ D/G ISOLATED “
and “ LT ISOLATED”