Engine LT Cooling Water System Isolation Procedure


GENERAL
·         Ask the chief engineer for permission and inform the bridge that maintenance will be carried out ( if applicable, i.e. maintenance on propulsion equipment / stabilizers / safety and lifesaving equipment etc ).
·         Inform senior watch engineer (SWE) about all maintenance that will be performed in the engine room.
·         Follow the log/tag-out procedure as per MR600 section 5.
·         Use necessary personal protection equipment (PPE).
JOB INSTRUCTION
·         Switch the engine to 1 – local
·         isolate the starting air on the engine, see “engine starting air isolation procedure”.
·         At the control stand place the emergency – off lever in the stop position ( see picture)
·         Refer to drawing “ main engine LT cooling water isolation V/V”s and :
Ø  Close valve ½ and attach the related tag.
Ø  Close the valve 2/2 and attach the related tag.
Ø  Relief the engine LT system pressure by opening the drain valve and attach the related tag.
·         On the ECR mimic panel display “ D/G ISOLATED “ and “ LT ISOLATED”

Tidak ada komentar: