Evaporator Operation
Switch Evaporator “off” in automatic mode
- Close the manual steam supply
valve and condensate valve
- Close HT to and from Heat
exchanger
- Open HT bypass
- Switch Evaporator OFF
When the Evaporator is completely OFF:
- Close valve seawater cooling pump
- Close return valve of HT after
heater
- Close overboard valve on ABB
- Main switch OFF
- Check chlorine system
- Open manual drain valve from heat
exchanger
Switch
Evaporator “ON” in automatic mode
- Start only when underway and at
sea!
- Open overboard valve on ABB ;
Check the manual overboard valves when using Evaporators 2 and 3
- Open distilled valve to potable /
distilled and open distilled valve behind flow counter
- Open return valve of HT after
heater slowly
- Open valve seawater cooling pump
- Make sure manual drain valve from
heat exchanger is closed
- Double check if all valves of the
Evaporator are in the correct position
- Main switch ON
- Press start
- When hot water pump is running:
Close HT bypass
- When all pumps are running: Crack
open the steam to the Evaporator (increase pressure slowly)
- Check chemical pump
- Check chlorine system